LOGO LWC
This optional, built with drawers, can be accessed from the roof for cleaning purposes, even during operation. The system of drawers, accompanied by casters, and fastening clamps, ensure correct sealing and extremely fast maintenance.

Product Features

 In industry, particularly in the food industry, it’s necessary to comply with strict hygiene regulations. Especially where heavy air humidity is prevalent, there’s a need for natural ventilation through a vent. Therefore it’s necessary to aerate the spaces regularly, without the intrusion of insects and small birds. The same can be applied to logistics centers and supermarkets. To avoid these situations, our products offer two solutions: anti-bird mesh and insect mesh. 

Tempered Alumininum

Roofs
0-15º

Opening 140º,150º & 160º

INSECT DRAWER

Alumininum

RAL 9005

Tempered Glass

Polycarbonate

Specifications

Typical Applications

Can be installed either into roofs or barrel vault daylighting systems. Particularly suitable for warehouses, logistics centres, production environments and industries. 

Materials

Tempered aluminium, sea water and corrosion resistant (EN AW 5754). 
Corrosion resistant bearings. 
Sealant applied so that there is no freezing, enabling the equipment to have low air permeability at the same time. 

Note: aluminum is supplied untreated as standard. Possibility of being supplied with electrostatic painting (in any RAL color). 

Dimensions

Roof opening width: 1000-2000 mm
Roof opening length: 1000-2000 mm

Opening Angle

Open angle from up to 90º. 

Controls Fire Ventilation

P2F: double pipe compressed air operation with fire function. 
M24V: electric motor. 

Controls Natural Ventilation

P2: double pipe compressed air operation. 
M230V: electric motor 

Bases

Double wall aluminium with insulation and TB, thermal break in the aluminium base. 

Weight

Depends on dimensions and type of infill.

Options

Custom Dimensions;
Powder coated design (any RAL color);
Bird or Insect Mesh/ Anti-Fall Grid 1200J

Regulations

The system has been tested and is certified in accordance with EN 12101-2

Weight

Depends on dimensions and type of infill.